Electronic category

Octave ultrasonic water meter  (DN40-300)

Octave ultrasonic water meter (DN40-300)

It is widely used for small flow users of large pipelines, such as community master meter, enterprises, schools, hospitals, fire meters, etc., especially for key users' trade settlement, master sub meter comparison, night leak detection and other occasions.

Detailed Introduction

Product application


It is widely used for small flow users of large pipelines, such as community master meter, enterprises, schools, hospitals, fire meters, etc., especially for key users' trade settlement, master sub meter comparison, night leak detection and other occasions.

Product features 


·Double channel ultrasonic metering, sampling frequency up to 100 times / second, metering more accurate and reliable.

·Without moving parts, it can keep accuracy for a long time and resist cold weather.

·High sensitivity and very low initiating flow (DN100 initiating flow is only 15L / h), which can be used for comparison of total sub meter and leak detection at night.

·The range ratio Q3 / Q1 can reach 500 times (the actual range ratio can reach 1000 times)

·There is almost no blind area in measurement, and the application scope is wider.

·The unique "black box" function can store more than 4000 pieces of historical data.

·Equipped with rectifier, not affected by flow field disturbance, low requirements for straight pipe section, and stronger installation applicability.

·IP68 waterproof grade, can work underwater for a long time.

·Three line LCD display (it can display accumulated flow, instantaneous flow, flow direction, alarm prompt, water temperature and other information at the same time)

·The display number of accumulated flow reaches 12, and the decimal point can be adjusted according to the demand.

`Remote transmission can be equipped with Cat.1/NB-IoT remote transmission terminal module

·The life expectancy of lithium battery is more than 10 years, and the six-year warranty is free.

     

Installation requirements

·Can be installed in any direction

·When not installed horizontally, the water outlet end is upward

·Measurement with full pipe.

·The sensitivity grade of flow profile is U0 and d0 (u2d2 is required when there are valves and screens in front of and behind the table)

Technical Parameters

Model

High Flow

Low Flow
DN 40 50 80 100 150 200 30040506580100150200250300
Basis of measurement range  GB/T778 Q3/Q1 250 500 500 500 500 500 500R250R500R500R500R500R500R500R500r500
QOverload flow  m3/h 50 50 80 125 313 500 12505050508012531550012501250
QCommon flow  m3/h 40 40 65 100 250 400 10004040406510025040010001000
QBoundary flow  m3/h 0.256 0.125 0.2 0.32 0.8 1.28 3.20.250.1250.1250.2000.3150.8001.253.153.15
Q1Minimum flow  m3/h 0.16 0.08 0.125 0.2 0.5 0.8 20.160.0800.0800.1250.2000.5000.80022
Humidity level T50
Pressure rating
1.6MPa
Degree of protection IP68
Pressure loss level △p16△p10△p16
On screen display It can display 12 digit cumulant (decimal point can be adjusted); four digit instantaneous flow


Installation Size
ModelHigh Flow
Low Flow
DN 40      (Threaded connection) 50 80 100 150 200 30040506580100150200250300
size Total length L mm 300 200 225 250 300 350 499300200200225250300350449499
height H mm 155 194 210 223 280 332 456155194210210223280332383456
h mm 35 40 90 103 140 165 24535409090103140165203245
width W mm 113 165 200 220 285 340 489113165185200220285340406489
weight Integral water meter kg 1.4 9 13 15 32 45 961.4911.51315

32

456896


 
Product diagram



 

 

CONTACT

SERVICE HOTLINE:400-108-1616

Sales Service Center:Qingjiang Road, Jianggan District, Hangzhou

R & D Production Base:No .22,15th Street, Qiantang New District, Hangzhou

E-mail:{dede:global.cfg_email/}

Phone/FAX:0571-86502742